M200 High-performance vector control frequency inverter (VSD) ac inverter
1,V/F control mode (One inverter control more than one motor---- 3motors most)
2,Open-loop vector control mode
3,Simple PLC can realize 16 speeds control
4,Built-in PID can compose close-loop control system conveniently. It is suitable for process-control system, like pressure and flow and etc.
5,Standard RS485 port supports MODBUS communication protocol, can compose a net to communicate with host controller, like touch panel , PLC and etc.
6,Sophisticated protection
2,Basic input and output
Input | Rated voltage and frequency | Single 220V,three-phase 220V,three-phase 380V;50Hz/60Hz |
Variable allowable value | voltage:-20% ~ +20% voltage unbalance:<3% frequency:±5%Hz | |
Output | Rated voltage | 0~220V/0~380V |
Frequency range | 0Hz~600Hz |
3,Main control functions
Main control function
| Modulation mode | Space voltage vector PWM |
Control mode | Sensorless vector control | |
Frequency accuracy | Digital setting:max frequency×±0.01%;Analog setting:max frequency×±0.2% | |
Frequency resolution | Digital setting:0.01Hz;Analog setting:max frequency×0.1% | |
Start frequency | 0.0Hz~10.00Hz | |
Torque rise | Auto torque rise, manual torque rise 1%~30.0% (Only be effective for V/F control mode) | |
Torque characteristics | 150% output of rated torque at 0.5Hz | |
V/F curve | Linear V/F curve, square V/F curve, user self-defining V/F curve | |
Acceleration/deceleration curve | The longest time: 6000s (settable in the range of 0.1~3600s). | |
DC braking | Be optional during both starting and stopping, the operating time: 0~50s | |
Jogging | Jogging frequency range: 0.1Hz~50.00Hz,jogging acceleration and deceleration time: 0.1~3600s. | |
Built-in PID | It is convenient for forming closed loop control system, applicable for course control like pressure and flow, etc. | |
Multi-speed running | Realize 16-speed running by control terminal. | |
Auto voltage adjustment | When main voltage changes, the output voltage may be kept constant by adjusting PWM output (AVR function). | |
Auto current limit | Limit in-service current automatically, so as to avoid tripping for fault caused by frequent over current. | |
Motor parameters automatic read | Reading the parameters from motor in order to achieve optimal controlling effect. |
4,Running function
Running function | Running command passage | Setting of operating panel; setting of control terminal; setting of serial port |
Frequency setting passage | setting of keyboard up, down keys; setting of functional code digits; setting of serial port, setting of terminal UP/DOWN, setting of analog voltage, setting of analog current ; setting of combination; | |
Switch input passage | 8-way programmable switching value input to set 32 functions. | |
Analog input passage | 2-way analog signal input, 0~20mA, 0~10V optional. | |
Analog output passage | 2-way analog signal output 0~10V ,0~20mA separately to get output of physical quantity like frequency and output frequency | |
Switch output passage | 2-way programmable open collector output; 1-way relay output signal; can output different physical quantities. |